MVHR unit guide

Nuaire MRXBOX95-WH1: specifications, filters & guide

MVHRNuaire

Wall-mounted Nuaire MVHR unit with two independent fans and four 150 mm spigots, stated to recover up to 95% of the heat normally lost from extract air.

  • Two independent fans
  • Heat exchanger
  • Interlocking wall bracket
  • Standard and opposite-hand versions
  • Speed 3 override

Buy replacement filters for MRXBOX95-WH1

Nuaire MRXBOX95-WH1 MVHR unit
Image: Nuaire

About the Nuaire MRXBOX95-WH1

The Nuaire MRXBOX95-WH1 is a wall-mounted mechanical ventilation unit with heat recovery, part of Nuaire’s WH1 range. It extracts moist air from wet rooms such as the kitchen, bathroom, en-suite and a utility room with a sink, and supplies filtered fresh air to habitable rooms such as bedrooms and the lounge. A heat exchanger passes heat from the outgoing extract air to the incoming air, and the manufacturer states that it can recover up to 95% of the heat that would otherwise be wasted. The system is designed to run continuously, so the unit must stay switched on at all times; turning it off can cause long-term damage to the unit and the building fabric.

Inside the casing are two independent fans, one for supply and one for extract, each with speed control for background and boost ventilation. Nuaire describes the WH1 system as designed for medium to large new build properties. Air enters and leaves through four 150 mm spigots on the top of the casing, and the unit hangs on an interlocking wall bracket. It needs a solid wall, or a stud partition backed by 25 mm MDF, and it can also be mounted in a loft space on an anti-vibration tray. Condensation from the heat exchanger is piped away through a condensate connection that must discharge through a trap or an equivalent airlock.

The installation manual covers four versions: the standard MRXBOX95-WH1, the opposite-hand MRXBOX95-WH1-OH, and the MRXBOX95AB-WH1 and MRXBOX95AB-WH1-OH, which add an integral automatic summer bypass and a humidity sensor with an adjustable set point. On the non-AB versions, the supply fan instead reduces to a trickle speed in excessive outside temperatures. An optional speed 3 switch overrides both speeds to run the fans at maximum airflow.

The two filters sit behind removable covers on the front panel. They are G3 filters measuring 188 x 413 mm, inspected after six months and replaced every 12 to 18 months; filters of this size are also available in G4 and M5 grades. The heat exchanger should be inspected every five years, and the five-year warranty is conditional on planned maintenance being carried out.

Key specs

Heat recovery (manufacturer's stated figure)
Up to 95% of the normally wasted heat
Fans
Two independent fans (supply and extract), each with full speed control for background and boost rates
Speed settings
Speed 1 and speed 2 per fan, plus speed 3 override to maximum airflow; speed 1 is limited to never exceed speed 2
Summer bypass, AB models
Integral automatic bypass operated by a wax actuator
Summer behaviour, non-AB models
Supply fan reduces automatically to trickle speed in excessive outside temperatures
Height
623 mm
Width
658 mm
Depth
432 mm
Minimum clear space in front, MRXBOX95-WH1
430 mm
Spigots
4 x 150 mm diameter, on the top of the unit
Recommended ducting
150 mm diameter circular or 204 x 60 mm rectangular, rigid ducting preferred
Maximum flexible duct
300 mm on each leg, pulled taut
Distance from unit to first duct bend
Minimum 300 mm recommended
External grille free area
Minimum 12,250 mm²
Condensate connection
Suitable for 21.5 mm diameter overflow pipe, solvent cement joint; discharge under a water level in a U-trap or equivalent airlock
Condensate pipe fall
Minimum 5° fall to the soil and vent pipe when using MVHR-DRAIN
Supply
Single phase, 50 Hz
Current consumption
1.3 A
Fuse rating
3 A
Mains connection
Supplied with a flexible cord (2 m pre-wired fly lead); connect to a fixed wiring installation via a fused isolator with minimum 3 mm contact separation; unit must be earthed
Filters fitted
Two removable G3 filters, accessed from the front panel
Filter size
188 x 413 mm
Grades available in this size
G3, G4 and M5
Replacement filter part number
778651
Filter service interval
Inspect after 6 months; replace every 12 to 18 months
Status indication
LEDs for speed 1, speed 2, speed 3, supply fan fault, extract fan fault, frost protection, filter change and (AB units) HX bypass
Humidity sensor, AB models
Internal sensor in the extract airflow with adjustable set point; least sensitive when turned fully clockwise
Optional controls
Speed 3 switch; Ecosmart sensor connector on the base of the unit; remote fail indicator MRXBOX95-RFI
Directives
EMC Directive 2014/30/EU; Low Voltage Directive 2014/35/EU

Replacement filters for the Nuaire MRXBOX95-WH1

How to change the filters

  1. Isolate the unit

    Electrically isolate the unit, the switched live and any Nuaire control from the mains and switched live supply, then allow at least two minutes for the fans to come to rest before removing any panel.

  2. Remove the two filter covers

    Take hold of the circular tab at each end of the filter covers on the front panel and pull the covers out.

  3. Draw out each filter

    Pull the removal loop on the front edge of each filter (the black tab on the visible end) to extract it from the unit.

  4. Inspect the filters

    Check each filter. Return it if it is serviceable, or replace it; the filters are inspected after 6 months and replaced every 12 to 18 months.

  5. Clean or replace

    Clean a reusable filter with a vacuum cleaner, or fit a new filter (G3, 188 x 413 mm).

  6. Refit the filters

    Slide the filters back into the unit.

  7. Refit the filter covers

    Replace the two filter covers and secure the tabs, then restore the power supply.

Manuals & downloads

MVHR Eco Range BrochureWEB
Installation and Maintenance ManualWEB
Energy LabelWEB
WH1 Installation and MaintenancePDF
MRXBOX95AB-WH1 Installation and MaintenancePDF
MRBOX95(AB)-WH1 RangePDF

Nuaire and all other manufacturer and product names, model numbers and part numbers on this page are the property of their respective owners and are used for identification only. MVHR.shop is an independent supplier of compatible filters. We are not affiliated with, endorsed by, sponsored by or approved by Nuaire or any other manufacturer named on this page.

This page is our own summary, written from documents published by the manufacturer (such as installation, user and product literature). We do not own the underlying information: all rights in the original documents, specifications, drawings and data remain with the manufacturer, and nothing here is intended to replace them.

The information is provided in good faith for general guidance only. Manufacturers revise their products and documents, specifications can differ between versions and production batches, and errors or omissions may exist, so we cannot guarantee that it is accurate, complete or up to date. Always check the manufacturer's current documentation and the rating label on your own unit before relying on any figure or part number. Nothing on this page is installation, electrical, commissioning or safety advice; work on ventilation equipment must be carried out by a competent person in line with the manufacturer's instructions and current regulations. To the fullest extent permitted by law we accept no liability for loss arising from reliance on this page. Nothing in this notice limits any liability that cannot be limited by law.

Links to other websites, including manufacturers' sites and documents, are provided for convenience only. We do not control, endorse or accept responsibility for their content, availability or privacy practices, and they may change or be removed without notice.

If you believe something on this page is wrong, or you are a rights holder with a concern, please contact us and we will review it promptly.

Specifications

Performance

Heat recovery (manufacturer's stated figure)
Up to 95% of the normally wasted heat
Fans
Two independent fans (supply and extract), each with full speed control for background and boost rates
Speed settings
Speed 1 and speed 2 per fan, plus speed 3 override to maximum airflow; speed 1 is limited to never exceed speed 2
Summer bypass, AB models
Integral automatic bypass operated by a wax actuator
Summer behaviour, non-AB models
Supply fan reduces automatically to trickle speed in excessive outside temperatures

Dimensions & weight

Height
623 mm
Width
658 mm
Depth
432 mm
Minimum clear space in front, MRXBOX95-WH1
430 mm

Connections & ducting

Spigots
4 x 150 mm diameter, on the top of the unit
Recommended ducting
150 mm diameter circular or 204 x 60 mm rectangular, rigid ducting preferred
Maximum flexible duct
300 mm on each leg, pulled taut
Distance from unit to first duct bend
Minimum 300 mm recommended
External grille free area
Minimum 12,250 mm²
Condensate connection
Suitable for 21.5 mm diameter overflow pipe, solvent cement joint; discharge under a water level in a U-trap or equivalent airlock
Condensate pipe fall
Minimum 5° fall to the soil and vent pipe when using MVHR-DRAIN

Electrical

Supply
Single phase, 50 Hz
Current consumption
1.3 A
Fuse rating
3 A
Mains connection
Supplied with a flexible cord (2 m pre-wired fly lead); connect to a fixed wiring installation via a fused isolator with minimum 3 mm contact separation; unit must be earthed

Filters

Filters fitted
Two removable G3 filters, accessed from the front panel
Filter size
188 x 413 mm
Grades available in this size
G3, G4 and M5
Replacement filter part number
778651
Filter service interval
Inspect after 6 months; replace every 12 to 18 months

Controls & features

Status indication
LEDs for speed 1, speed 2, speed 3, supply fan fault, extract fan fault, frost protection, filter change and (AB units) HX bypass
Humidity sensor, AB models
Internal sensor in the extract airflow with adjustable set point; least sensitive when turned fully clockwise
Optional controls
Speed 3 switch; Ecosmart sensor connector on the base of the unit; remote fail indicator MRXBOX95-RFI

Approvals & compliance

Directives
EMC Directive 2014/30/EU; Low Voltage Directive 2014/35/EU

At a glance

Unit type
MVHR
Manufacturer
Nuaire
Product range
Nuaire WH1 wall mounted range
Versions
MRXBOX95-WH1, MRXBOX95-WH1-OH, MRXBOX95AB-WH1, MRXBOX95AB-WH1-OH
Handing
Standard and opposite hand (OH)
Mounting
Wall mounted on a solid wall, or a stud partition with 25 mm MDF behind the board; loft mounting on an AV-WH1 tray
Spigots
4 x 150 mm diameter, top of unit
Designed for
Medium to large new build properties
Guarantee
5 years: parts and labour in year 1, parts only in years 2 to 5
  • Up to 95%Heat recovery (manufacturer's stated figure)
  • 4 x 150 mmDuct spigots
  • 2 x G3Filters fitted (188 x 413 mm)
  • 1.3 ACurrent consumption (3 A fuse)
  • 623 x 658 x 432 mmHeight x width x depth
  • 5 yearsWarranty

Nuaire MRXBOX95-WH1 features

All models

Two independent fans

Separate supply and extract fans each have their own speed control, so background and boost flow can be set for each side of the system during commissioning.

Heat exchanger

The heat exchanger transfers heat from the extract air to the incoming air; the manufacturer states it can recover up to 95% of the heat normally wasted.

Interlocking wall bracket

A two-part bracket is fixed to the wall and to the rear of the unit, and the unit simply interlocks over the wall-mounted part. The unit must be level in all three dimensions to avoid drip tray overflow.

Standard and opposite-hand versions

The OH versions mirror the airflow arrangement of the standard units, so the spigot layout can be matched to the duct runs in the dwelling.

Speed 3 override

An optional speed 3 switch overrides both speed 1 and speed 2 and drives the fans to maximum airflow, for example from a kitchen switch.

Front-access filters

Both G3 filters are removed from the front by pulling off two filter covers, then drawing each filter out by its loop, with no need to take the unit off the wall.

AB models only

Automatic summer bypass

A wax actuator opens the bypass damper automatically so air can pass around the heat exchanger and deliver fresh filtered air in warmer months.

Integral humidity sensor

A sensor in the extract airflow boosts the unit to the commissioned boost speed when humidity exceeds an adjustable set point on the front of the unit. It should not be relied on alone, so a switch local to the wet rooms is also used.

Non-AB models only

Thermal bypass behaviour

In excessive outside temperatures the supply fan reduces automatically to a trickle speed to help prevent overheating, so additional ventilation such as open windows or trickle vents may be needed.

Installing the Nuaire MRXBOX95-WH1

The unit is installed indoors on a solid wall, away from direct sources of frost, heat, water spray or moisture generation, using the supplied interlocking bracket; a gypsum block or ordinary stud wall is not sufficient unless a 25 mm minimum MDF panel is solidly fixed behind the board, extending over at least three studs at no more than 400 mm centres and ideally from floor to ceiling (minimum 2 m). Allow at least 430 mm clear space in front of the MRXBOX95-WH1 for cover removal and filter changes, and install the unit level in all three dimensions.

Use rigid 150 mm circular or 204 x 60 mm rectangular ducting where possible, insulate the intake and exhaust ducts, keep intake terminals at least 300 mm from a gas boiler balanced flue as a guide, and pipe the condensate through a filled U-trap or equivalent airlock. Remove the protective film from the filters before commissioning, and commission with a calibrated moving vane anemometer and hood.

Installation must be carried out by competent personnel, and the electrical connection by a qualified electrician. Isolate the unit, switched live and Nuaire control from the mains before any work.